The ToxiRAE Pro single gas detectors from Honeywell's RAE systems range of portable gas detection are compact, reliable, and easy to use offering the flexibility of easily swappable sensors that will allow you to monitor for different gases in different situations. Wireless monitoring for toxic gases and oxygen will keep your workers safe by transmitting collected data to a central command location in real time.
The ToxiRAE Pro won't get in the way of workers doing their jobs and provides unmistakable five-way local and remote alarms if a threat is detected or a man is down.
It also offers the flexibility of easily swappable sensors to monitor different gases in different situations.
Single gas detector for LEL / O2 / CO / H2S / SO2 / CO2 / NH3 / CI2 / CI02 / Et0-A / Et0-B / HCH0 / H2 / CH3-SH / NO / PH3
contact us for more information about the ToxiRAE Pro Gas Detectors
BUY NOW from the Gas Detector Shop by Aegis Sales & Service
ToxiRAE Pro FamilyPORTABLE / EASY TO USE / RELIABLE
TICs | VOCs | CO2 | O2 | LEL Compact and lightweight
IP54 (PID) and IP65 (EC, LEL, CO2)
Five-way alarm notification - man down & four instrument alarms
Three months of continuous data logging
|
Featuring:
- Personal wireless monitor for toxic gases and oxygen
- Swap out sensors for different gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, hydrogen cyanide, nitric oxide, phosphine, sulfur dioxide, and more
- Sensors store calibration data even when swapped out
- 5-way local and remote wireless alarm system
- Largest display in class
- Water-, dust-, and shock-resistant
- Compatible with AutoRAE 2 (Fully automatic bump testing and calibration)
- Built-in man-down alarm
- Most sensors can be shared with the MultiRAE instrument family
- Clandestine Labs
- Emergency Response
- Exploration
- Fire Overhaul
- Fracking
- Hazmat Response
- Plant Shutdown & Turn-Around
- Residential Calls
- Urban Search & Rescue
- Worker Exposure
Applications
- CBRNE
- Clandestine Labs
- Emergency Response
- Environmental Cleanups/ Remediation
- Exploration
- Fire Overhaul
- Fracking
- Hazmat Response
- Leak Detection
- Plant Shutdown & Turn-Around
- Residential Calls
- Urban Search & Rescue
- Worker Exposure
Specifications
Size | 11.8 x 6 x 3 cm |
Weight | 220g |
Sensor | Over 20 intelligent interchangeable field-replaceable electrochemical sensors |
Battery | Rechargeable Li-ion battery |
- Operating Time: > 30 hours (normal operation, non-wireless) - Recharge Time: < 4 hours through charging cradle | |
- Recharge Time: < 4 hours through charging cradle | |
Display | Graphical LCD display iwth white LED backlighting (activated when monitor is in alarm or with a button press) |
Display Readout | - Real-time reading of gas concentrations in parts per million (ppm) or mg/m3, battery status; data logging on/off: wireless on/off and reception quality |
- STEL, TWA, and peak values | |
Keypad | 2 buttons for operation and programming |
Sampling | Diffusion |
Calibration | Automatic AutoRAE 2 Test and Calibration System2 or manual |
Alarm Modes | - Wireless remote alarm notifications; audible (95dB @ 30cm), vibration, visible alarm (flashing bright red LEDs), and on-screen indication of alarm conditions |
- Man Down Alarm with pre-alarm and real-time remote wireless notification | |
Data logging | - Continuous data logging with a three-month capacity (at one-minute intervals) |
- User-configurable data logging interval (from 1 to 3,6000 seconds) | |
Communication & Data Download | - Data download and instrument set-up on PC via charging and PC comm. cradle |
- Data download via AutoRAE 2 Automatic Test and Calibration System | |
- Wireless data and status transmission1 via built-in RF modem (optional) | |
Wireless Network | ProRAE Guardian Real-Time Wireless Safety System or Closed-Loop Network with the EchoVIew Host |
Wireless Range (Typical) | ToxiRAE Pro to Mesh Router, EchoView Host or Mesh Reader2 - 200 metres |
ToxiRAE Pro at RAELink3 MEsh or RAELink3 Z1 Mesh modems - 100 metres | |
Wireless Frequency | ISM license-gree bank, IEEE 802.15.4 Sub 1GHz |
Wireless Approvals | FCC Part 15, CE R&TTE |
Operating Temperature | -20ºc to +55ºc |
Humidity | 0% to 95% relative humidity (non-condensing) |
Dust & Water Resistance | IP65 rating for dust and water ingress protection |
Hazardous Location Approvals | The unit cannot be used in hazardous areas |
Safety Certifications | ATEX: CE Ex II 1G, Ex ia IIC Ga T4 / IECEx: Ex ia IIC Ga T4 |
EMC / RFI | EMC directive: 2004/108/EC |
Warranty | - Two years on non-consumable components and CO, H2S, and O2 sensors |
- One year on all other sensors, battery, and other consumable parts | |
Radio Module | Supports RM9000 |
1 Wireless units have a functioning RF modem and are ready for wireless deployments; non-wireless units cannot be upgraded to wireless. Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission.
2 Contact Aegis Sales & Service for availability
3 It is recommended that sensors are calibrated on installation
SPECIFICATIONS ARE SUBJECT TO CHANGE
Sensor Specifications
Sensor | Order Code | Range | Resolution |
Ammonia (NH3) | GDC03-0950-000 | 0 to 100 ppm | 1 ppm |
Carbon Monoxide (CO) | GDC03-0906-000 | 0 to 500 ppm | 1 ppm |
Carbon Monoxide (CO), Ext. Range | GDC03-0903-000 | 0 to 2,ooo ppm | 10 ppm |
Carbon Monoxide (CO), H2 - comp | GDC03-0979-000 | 0 to 2,000 ppm | 10 ppm |
Chlorine (CI2) | GDC03-0978-000 | 0 t0 50 ppm | 0.1 ppm |
Chlorine Dioxide (CI02) | GDC03-0956-000 | 0 to 1 ppm | 0.03 ppm |
Ethylene Oxide (Et0-A) | GDC03-0954-000 | 0 to 100 ppm | 1 ppm |
Ethylene Oxide (Et0-B) | GDC03-0922-100 | 0 to 10 ppm | 0.1 ppm |
Ethylene Oxide (Et0-C, HR), Ext. Range | GDC03-0923-100 | 0 to 500 ppm | 10 ppm |
Formaldehyde (HCH0) | GDC03-0982-000 | 0 to 10 ppm | 0.05 ppm |
Hydrogen (H2) | GDC03-0981-000 | 0 to 1,000 ppm | 10 ppm |
Hydrogen Sulfide (H2S) | GDC03-0907-001 | 0 to 100 ppm | 0.1 ppm |
Hydrogen Sulfide (H2S), Ext. Range | GDC03-0904-000 | 0 to 1,000 ppm | 1 ppm |
Methyl Mercaptan (CH3-SH) | GDC03-0980-000 | 0 to 10 ppm | 0.1 ppm |
Nitric Oxide (N0) | GDC03-0974-000 | 0 to 250 ppm | 0.5 ppm |
Nitrogen Dioxide (N02) | GDC03-0975-000 | 0 to 20 ppm | 0.1 ppm |
Oxygen (O2) | GDC03-0942-000 | 0 to 30% Vol. | 0.1% Vol |
Phosphine (PH3) | GDC03-0976-000 | 0 to 20 ppm | 0.1 ppm |
Sulfur Dioxide (S02) | GDC03-0973-100 | 0 to 20 ppm | 0.1 ppm |
Available Accessories
AutoRAE 2 Automatic Test & Calibration DockSimplify bump testing and calibration of your RAE Systems gas monitors with the AutoRAE 2. Versatile and modular, it can be deployed as a single, stand-alone unit to calibrate one instrument at a time, or networked to support up to 10 units at once and calibrate for up to five distinct gases. One-touch bump testing and single-button operation for calibration make it easy to use. |
Multi-unit charging stationThe multi-gang charger accessory allows for the ToxiRAE Pro to be charged. Suited for use with RAE Systems ToxiRAE Pro, ToxiRAE Pro LEL, ToxiRAE Pro CO2, and ToxiRAE Pro PID by Honeywell Analytics. |
ToxiRAE Pro comes with:
- ToxiRAE Pro monitor with a sensor as specified, alligator clip, rechargeable battery
- Protective rubber boot
- Charging and PC communication cradle
- PC communication cable
- AC adapter (100 to 240 V, 50/60 Hz AC to 12 V DC)
- Calibration adapters
- Quick Start Guide
- CD with documentation
- Calibration certificate