HEAD OFFICE 07 38651139  CHINCHILLA 1800 234 477

ToxiRAE Pro Single Portable Gas Detector

ToxiRAE Pro Single Sensor Gas Detector by RAE Systems from Honeywell

The ToxiRAE Pro single gas detectors from Honeywell's RAE systems range of portable gas detection are compact, reliable, and easy to use offering the flexibility of easily swappable sensors that will allow you to monitor for different gases in different situations. Wireless monitoring for toxic gases and oxygen will keep your workers safe by transmitting collected data to a central command location in real time.

The ToxiRAE Pro won't get in the way of workers doing their jobs and provides unmistakable five-way local and remote alarms if a threat is detected or a man is down.

It also offers the flexibility of easily swappable sensors to monitor different gases in different situations.

Single gas detector for LEL / O2 / CO / H2S / SO2 / CO2 / NH3 / CI2 / CI02 / Et0-A / Et0-B / HCH0 / H2 / CH3-SH / NO / PH3

 

    contact us   for more information about the ToxiRAE Pro Gas Detectors

BUY NOW   from the Gas Detector Shop by Aegis Sales & Service

ToxiRAE Pro Family

PORTABLE / EASY TO USE / RELIABLE
 

TICs | VOCs | CO2 | O2 | LEL

Compact and lightweight 
IP54 (PID) and IP65 (EC, LEL, CO2)
Five-way alarm notification - man down & four instrument alarms
Three months of continuous data logging
RAE by Honeywell - ToxiRAE Pro Family

 

Featuring:

  • Personal wireless monitor for toxic gases and oxygen 
  • Swap out sensors for different gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, hydrogen cyanide, nitric oxide, phosphine, sulfur dioxide, and more
  • Sensors store calibration data even when swapped out
  • 5-way local and remote wireless alarm system
  • Largest display in class
  • Water-, dust-, and shock-resistant
  • Compatible with AutoRAE 2 (Fully automatic bump testing and calibration)
  • Built-in man-down alarm
  • Most sensors can be shared with the MultiRAE instrument family 
  • Clandestine Labs
  • Emergency Response
  • Exploration
  • Fire Overhaul
  • Fracking
  • Hazmat Response
  • Plant Shutdown & Turn-Around
  • Residential Calls
  • Urban Search & Rescue
  • Worker Exposure

 

Applications

  • CBRNE
  • Clandestine Labs
  • Emergency Response
  • Environmental Cleanups/ Remediation
  • Exploration
  • Fire Overhaul
  • Fracking
  • Hazmat Response
  • Leak Detection
  • Plant Shutdown & Turn-Around
  • Residential Calls
  • Urban Search & Rescue
  • Worker Exposure

 

Specifications

Size 11.8 x 6 x 3 cm
Weight  220g
Sensor  Over 20 intelligent interchangeable field-replaceable electrochemical sensors
Battery  Rechargeable Li-ion battery 
- Operating Time: > 30 hours (normal operation, non-wireless) - Recharge Time: < 4 hours through charging cradle
- Recharge Time: < 4 hours through charging cradle
Display Graphical LCD display iwth white LED backlighting (activated when monitor is in alarm or with a button press)
Display Readout - Real-time reading of gas concentrations in parts per million (ppm) or mg/m3, battery status; data logging on/off: wireless on/off and reception quality
- STEL, TWA, and peak values
Keypad 2 buttons for operation and programming 
Sampling Diffusion 
Calibration Automatic AutoRAE 2 Test and Calibration System2 or manual 
Alarm Modes - Wireless remote alarm notifications; audible (95dB @ 30cm), vibration, visible alarm (flashing bright red LEDs), and on-screen indication of alarm conditions
- Man Down Alarm with pre-alarm and real-time remote wireless notification
Data logging - Continuous data logging with a three-month capacity (at one-minute intervals)
- User-configurable data logging interval (from 1 to 3,6000 seconds)
Communication & Data Download - Data download and instrument set-up on PC via charging and PC comm. cradle 
- Data download via AutoRAE 2 Automatic Test and Calibration System
- Wireless data and status transmission1 via built-in RF modem (optional)
Wireless Network ProRAE Guardian Real-Time Wireless Safety System or Closed-Loop Network with the EchoVIew Host
Wireless Range (Typical) ToxiRAE Pro to Mesh Router, EchoView Host or Mesh Reader2 - 200 metres 
ToxiRAE Pro at RAELink3 MEsh or RAELink3 Z1 Mesh modems - 100 metres
Wireless Frequency ISM license-gree bank, IEEE 802.15.4 Sub 1GHz
Wireless Approvals FCC Part 15, CE R&TTE
Operating Temperature -20ºc to +55ºc 
Humidity 0% to 95% relative humidity (non-condensing)
Dust & Water Resistance IP65 rating for dust and water ingress protection 
Hazardous Location Approvals The unit cannot be used in hazardous areas
Safety Certifications ATEX: CE Ex II 1G, Ex ia IIC Ga T4   / IECEx: Ex ia IIC Ga T4
EMC / RFI EMC directive: 2004/108/EC
Warranty - Two years on non-consumable components and CO, H2S, and O2 sensors 
- One year on all other sensors, battery, and other consumable parts
Radio Module Supports RM9000

1 Wireless units have a functioning RF modem and are ready for wireless deployments; non-wireless units cannot be upgraded to wireless. Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission.

2 Contact Aegis Sales & Service for availability

3 It is recommended that sensors are calibrated on installation

SPECIFICATIONS ARE SUBJECT TO CHANGE

Sensor Specifications 

 Sensor Order Code Range Resolution
 Ammonia (NH3) GDC03-0950-000 0 to 100 ppm 1 ppm
 Carbon Monoxide (CO) GDC03-0906-000 0 to 500 ppm 1 ppm
 Carbon Monoxide (CO), Ext. Range GDC03-0903-000 0 to 2,ooo ppm 10 ppm
 Carbon Monoxide (CO), H2 - comp GDC03-0979-000 0 to 2,000 ppm 10 ppm
 Chlorine (CI2) GDC03-0978-000 0 t0 50 ppm 0.1 ppm
 Chlorine Dioxide (CI02) GDC03-0956-000 0 to 1 ppm 0.03 ppm
 Ethylene Oxide (Et0-A) GDC03-0954-000 0 to 100 ppm 1 ppm
 Ethylene Oxide (Et0-B) GDC03-0922-100 0 to 10 ppm 0.1 ppm
 Ethylene Oxide (Et0-C, HR), Ext. Range GDC03-0923-100 0 to 500 ppm 10 ppm
 Formaldehyde (HCH0) GDC03-0982-000 0 to 10 ppm 0.05 ppm
 Hydrogen (H2) GDC03-0981-000 0 to 1,000 ppm 10 ppm
 Hydrogen Sulfide (H2S) GDC03-0907-001 0 to 100 ppm 0.1 ppm
 Hydrogen Sulfide (H2S), Ext. Range GDC03-0904-000 0 to 1,000 ppm 1 ppm
 Methyl Mercaptan (CH3-SH) GDC03-0980-000 0 to 10 ppm 0.1 ppm
 Nitric Oxide (N0) GDC03-0974-000 0 to 250 ppm 0.5 ppm
 Nitrogen Dioxide (N02) GDC03-0975-000 0 to 20 ppm 0.1 ppm
 Oxygen (O2) GDC03-0942-000 0 to 30% Vol. 0.1% Vol
 Phosphine (PH3) GDC03-0976-000 0 to 20 ppm 0.1 ppm
 Sulfur Dioxide (S02) GDC03-0973-100 0 to 20 ppm 0.1 ppm

 Available Accessories

AutoRAE 2 Calibration Dock for the ToxiPro by RAE Systems Honeywell

AutoRAE 2 Automatic Test & Calibration Dock

Simplify bump testing and calibration of your RAE Systems gas monitors with the AutoRAE 2. Versatile and modular, it can be deployed as a single, stand-alone unit to calibrate one instrument at a time, or networked to support up to 10 units at once and calibrate for up to five distinct gases. One-touch bump testing and single-button operation for calibration make it easy to use. 

Multi Charger for the ToxiRAE Pro by RAE Systems Honeywell

Multi-unit charging station

The multi-gang charger accessory allows for the ToxiRAE Pro to be charged. Suited for use with RAE Systems ToxiRAE Pro, ToxiRAE Pro LEL, ToxiRAE Pro CO2, and ToxiRAE Pro PID by Honeywell Analytics.

 

ToxiRAE Pro comes with:

  • ToxiRAE Pro monitor with a sensor as specified, alligator clip, rechargeable battery
  • Protective rubber boot
  • Charging and PC communication cradle
  • PC communication cable
  • AC adapter (100 to 240 V, 50/60 Hz AC to 12 V DC)
  • Calibration adapters
  • Quick Start Guide
  • CD with documentation
  • Calibration certificate

 

 

DOWNLOAD PDF  for the ToxiRAE Pro range

 

DOWNLOAD PDF  for the ToxiRAE Pro CO2

 

DOWNLOAD PDF  for the ToxiRAE Pro PID