Si-RD3 Refrigerant Leak Detector

Si RD3 Refrigerant Leak Detector by Sauermann The Sauermann Si-RD3 refrigerant leak detector uncovers leaks of most common refrigerant gases to a high degree of sensitivity, including all HCFC and HFC refrigerants, R1234yf, R1234ze, R290, R600a, and 5% hydrogen–95% nitrogen mixtures (Nidron 5 and Trace-A-Gas). 

      contact us   for more information on Sauermann's Si-RD3 Portable Refrigerant Leak Detector

 The Si-RD3 handheld leak detector features:

  • Detects: all HFCF and HFC refrigerants, R1234yf, R1234ze, R290, R600a, and 5% hydrogen - 95% nitrogen mixtures (Nidron 5, Trace-A-Gas)
  • Manual and automatic autozero. Immediately ready to use with no presets
  • Heated diode sensor
  • 3 modes: Low, Normal, and High sensitivity

 

Reglementations

  • Minimum threshold of sensitivity: Fixed <1 g/year at 3mm. In moving air: 2g/year, 2cm at 3mm
  • Minimum time of detection (1 g/year): 1 second
  • Autozero: 2 seconds
  • Recuperation time after exposition: from 1 to 10 seconds (depending on detection level and threshold of sensitivity)

The Si-RD3 comes with a 2-year guarantee against any manufacturing defects and is also supplied with a verification certificate, transport case, filter, and quick start guide. 

We recommend that you regularly check, adjust and maintain your devices to guarantee a constant quality level of your measurements. According to the quality assurance standards, Sauermann recommends yearly checking. Sauermann also recommends regular checking of the nozzle of the detector and that its filter is clean in order to guarantee the performance of the device.

.

Technical Specifications for the Sauermann Si-RD3 Refrigerant Leak Detector 

 MODE  INDICATIVE MEASURING RANGE  VISUAL ALARM
 Low sensitivity ("L" on the device)  from 0 to 300 g/year  all the LEDs (8) for 300 g/year
 Normal sensitivity ("M" on the device)  from 0 to 30 g/year  all the LEDs (8) for 30 g/year
 High sensitivity ("H" on the device)  from 0 to 3 g/year  all the LEDs (8) for 3 g/year

 

General Specifications of the Sauermann Si-RD3 Refrigerant Leak Detector 

 Main detected range
 HFC: R134a, R404a, R407c, R410a, R32, R422a/b/c/d, R425a, R507a, R125
 HCFC: R22
 CFC: R12, R502
 Others: 5% hydrogen - 95% nitrogen (Nidron 5, Trace-A-Gas), R290, R600a, R1234yf, R1234ze
 Measuring element  Semiconductor sensor
 Display
 13 LEDs:
 8 for the graphic visualization of thresholds
 3 for the sensitivity of detection
 2 for the battery level and manual autozero
 Induction  LED: gradual lighting up when the gas concentration increases
 Audible: the beep frequency increases when the gas concentration increases
 Probe  Flexible, 300mm length
 Autonomy  > 12 hours
 Housing
 ABS topsafe, protection IP54
 Keypad  3 keys
 Power Supply
 4 x AAA LR03 1.5 V batteries
 European directives
 2014/30/EU EMC; 2014/35/EU Low Voltage; RoHS 2011/65/EU (EU)2015/863; 2012/19/EU WEEE
 Ambience  Air and non-corrosive gases
 Conditions of use
 (°C, %RH, m)
 From 0 to +50 °C. In non-condensing conditions.
 From 0 to 2000 m.
 Storage Temperature  From -20 to +80 °C 
 Auto-extinction  15 minutes
 Weight  295g

 

Supplied with:

  • Sauermann verification certificate
  • Transport case
  • Quick Start Guide
  • Filter

Warranty for the Suaermeann Si-RD3 handheld leak monitor

The Si-RD3 has a 2-year guarantee against any manufacturing defect.

 

Maintenance

We recommend that you regularly check, adjust and maintain your devices to guarantee a constant quality level of your measurements. According to the quality assurance standards, Sauermann recommends yearly checking.


Sauermann also recommends regular checking of the nozzle of the detector and that its filter is clean in order to guarantee the performance of the device.

 

Si-RD3 Accessories

 Part No

 Name / Description

 GDCQ-15
 Magnetic protective housing
 GDSIACCSC
 Softcase