The Sauermann Si-RD3 refrigerant leak detector uncovers leaks of most common refrigerant gases to a high degree of sensitivity, including all HCFC and HFC refrigerants, R1234yf, R1234ze, R290, R600a, and 5% hydrogen–95% nitrogen mixtures (Nidron 5 and Trace-A-Gas).
contact us for more information on Sauermann's Si-RD3 Portable Refrigerant Leak Detector
The Si-RD3 handheld leak detector features:
- Detects: all HFCF and HFC refrigerants, R1234yf, R1234ze, R290, R600a, and 5% hydrogen - 95% nitrogen mixtures (Nidron 5, Trace-A-Gas)
- Manual and automatic autozero. Immediately ready to use with no presets
- Heated diode sensor
- 3 modes: Low, Normal, and High sensitivity
Reglementations
- Minimum threshold of sensitivity: Fixed <1 g/year at 3mm. In moving air: 2g/year, 2cm at 3mm
- Minimum time of detection (1 g/year): 1 second
- Autozero: 2 seconds
- Recuperation time after exposition: from 1 to 10 seconds (depending on detection level and threshold of sensitivity)
The Si-RD3 comes with a 2-year guarantee against any manufacturing defects and is also supplied with a verification certificate, transport case, filter, and quick start guide.
We recommend that you regularly check, adjust and maintain your devices to guarantee a constant quality level of your measurements. According to the quality assurance standards, Sauermann recommends yearly checking. Sauermann also recommends regular checking of the nozzle of the detector and that its filter is clean in order to guarantee the performance of the device.
.
Supplied with: Warranty for the Suaermeann Si-RD3 handheld leak monitor The Si-RD3 has a 2-year guarantee against any manufacturing defect. Maintenance We recommend that you regularly check, adjust and maintain your devices to guarantee a constant quality level of your measurements. According to the quality assurance standards, Sauermann recommends yearly checking. Technical Specifications for the Sauermann Si-RD3 Refrigerant Leak Detector
MODE
INDICATIVE MEASURING RANGE
VISUAL ALARM
Low sensitivity ("L" on the device)
from 0 to 300 g/year
all the LEDs (8) for 300 g/year
Normal sensitivity ("M" on the device)
from 0 to 30 g/year
all the LEDs (8) for 30 g/year
High sensitivity ("H" on the device)
from 0 to 3 g/year
all the LEDs (8) for 3 g/year
General Specifications of the Sauermann Si-RD3 Refrigerant Leak Detector
Main detected range
HCFC: R22
CFC: R12, R502
Others: 5% hydrogen - 95% nitrogen (Nidron 5, Trace-A-Gas), R290, R600a, R1234yf, R1234ze
Measuring element
Semiconductor sensor
8 for the graphic visualization of thresholds
2 for the battery level and manual autozero
Induction
LED: gradual lighting up when the gas concentration increases
Audible: the beep frequency increases when the gas concentration increases
Probe
Flexible, 300mm length
Autonomy
> 12 hours
Housing
Keypad
3 keys
European directives
Ambience
Air and non-corrosive gases
Storage Temperature
From -20 to +80 °C
Auto-extinction
15 minutes
Weight
295g
Sauermann also recommends regular checking of the nozzle of the detector and that its filter is clean in order to guarantee the performance of the device.Si-RD3 Accessories
Part No